Owner Resources

Spray Foam PPE: Respirators, Suits and Ventilation

A man in work gloves spraying foam sealant around a door frame beside pink fiberglass insulation in the wall

Spray foam PPE starts with the respirator, and for a crew whose work calls for one, OSHA treats it as a program rather than a purchase: a written plan, a medical evaluation, training, and for a tight-fitting respirator a fit test. Gloves, coveralls and eye protection come next, then ventilation, and last, when people may come back inside.

Why spray foam work puts respirators first

The chemistry sets the order. EPA’s archived page on chemical exposures from spray foam says “Spray application generates isocyanate vapors and aerosols.” It adds that “Research data indicate that inhalation exposures during SPF insulation will typically exceed Occupational Safety and Health Administration (OSHA) occupational exposure limits (OELs) and require skin, eye and respiratory protection.” The same page says “Cutting or trimming the foam as it hardens (tack-free phase) may generate dust that may contain unreacted isocyanates and other chemicals.”

The health stakes explain why the gear is planned as a set. NIOSH’s archived isocyanates page says “Isocyanates can also sensitize workers, making them subject to severe asthma attacks if they are exposed again.” PPE still ranks behind the engineering controls. NIOSH says “Engineering controls such as closed systems and ventilation should be the principal method for minimizing isocyanate exposure in the workplace.” OSHA’s respiratory protection standard says “the primary objective shall be to prevent atmospheric contamination”, and “When effective engineering controls are not feasible, or while they are being instituted, appropriate respirators shall be used pursuant to this section.”

The written respirator program OSHA asks for

Where respirators are needed, the standard asks for a document, not masks on a shelf. Its program provision says “In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures.” For construction work, OSHA’s construction respirator rule says “The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter.”

The program has named parts, included as applicable: “Procedures for selecting respirators for use in the workplace”, “Medical evaluations of employees required to use respirators”, “Fit testing procedures for tight-fitting respirators” and “Procedures for proper use of respirators in routine and reasonably foreseeable emergency situations”, then upkeep, breathing air, training and “Procedures for regularly evaluating the effectiveness of the program”.

Somebody has to own it. The standard says “The employer shall designate a program administrator who is qualified by appropriate training or experience that is commensurate with the complexity of the program”, and “The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use.”

Choosing the respirator for isocyanate vapor and mist

The employer chooses the respirator from the hazard, and for vapors the rule narrows the field. The standard says “The employer shall select a NIOSH-certified respirator.” Its hazard evaluation “shall include a reasonable estimate of employee exposures to respiratory hazard(s)”, and where the employer “cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH”, the standard’s abbreviation for an atmosphere that poses an immediate threat to life, would cause irreversible adverse health effects, or would impair escape.

In an atmosphere that is not IDLH, the standard’s rule for protection against gases and vapors allows “An atmosphere-supplying respirator”, or an air-purifying respirator equipped with “an end-of-service-life indicator (ESLI) certified by NIOSH for the contaminant”, or, where no such indicator suits the workplace, an air-purifying respirator used under a change schedule for canisters and cartridges based “on objective information or data that will ensure that canisters and cartridges are changed before the end of their service life.” The program must then describe the data behind that schedule. IDLH atmospheres have their own list in the same standard.

The foam maker’s paperwork is where the selection starts. EPA’s archived ventilation guidance for spray foam says “SPF manufacturer’s recommendations for proper respiratory and other protective equipment can be found in the product’s material safety data sheet (MSDS).” and “Generally, these recommendations will include the use of full face-piece or hooded supplied air respirators.” NIOSH’s respirator page adds that “a respirator’s effectiveness depends heavily on proper fit and use.”

Medical evaluation, fit testing and the facepiece seal

Before anyone sprays in a tight-fitting respirator, the standard puts a medical evaluation and a fit test ahead of the work. It says “The employer shall provide a medical evaluation to determine the employee’s ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace.” EPA’s archived workplace guidance lists a related step under preparation: “Receive medical surveillance to ensure applicators and helpers are healthy enough to wear a respirator.”

The fit test comes next. The employer “shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter.”

A tight-fitting respirator has its seal checked each time it goes on. The employer “shall not permit respirators with tight-fitting facepieces to be worn by employees who have:” “Facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function”. And “For all tight-fitting respirators, the employer shall ensure that employees perform a user seal check each time they put on the respirator”.

Training, checks before each use and the paperwork behind them

The standard says “The employer shall provide the training prior to requiring the employee to use a respirator in the workplace.” Each employee must be able to show knowledge of items that include “How to inspect, put on and remove, use, and check the seals of the respirator”, and “Retraining shall be administered annually”, as well as when changes in the workplace or the respirator make earlier training obsolete. Applicator training programs are a separate subject; our applicator certification guide takes them up.

The checks continue on the job. “All respirators used in routine situations shall be inspected before each use and during cleaning”. Workers leave the respirator use area “If they detect vapor or gas breakthrough, changes in breathing resistance, or leakage of the facepiece”, and the employer “must replace or repair the respirator before allowing the employee to return to the work area.”

Keep the paper where you can find it. The standard says “The employer shall establish a record of the qualitative and quantitative fit tests administered to an employee” and “A written copy of the current respirator program shall be retained by the employer.” EPA’s contractor checklist for professional high-pressure spray foam, marked “U.S. EPA Working Draft” and described as “a voluntary aid to protect against potential risks from SPF; it is not a regulatory compliance tool”, suggests you “Maintain an on-site copy of the contractor’s written safety plan.”

Gloves, coveralls and eye protection for the spray zone

Skin and eyes stay covered for the whole job, from spraying through trimming and clean-up. EPA’s archived workplace practices page says to “Make sure workers wear protective equipment at all times to avoid exposure to vapor, mist, particulates and dust, including” an “Appropriate respirator”, “Chemical resistant (e.g., nitrile) gloves” and “Chemical resistant clothing”. The working-draft checklist for professional high-pressure spray foam says “Use chemically resistant (e.g., synthetic rubber) gloves, protective coveralls, eye protection, head coverings, and foot protection.”

OSHA’s construction PPE standard sets the baseline. Its text requires protective equipment, protective clothing and respiratory devices among it, to be provided, used and maintained in a sanitary and reliable condition “wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.” It adds that employers must ensure the equipment is “of safe design and construction for the work to be performed” and is “selected to ensure that it properly fits each affected employee.”

The gear stays on after the spray. EPA’s archived workplace page says to “Make sure workers wear personal protective equipment while cutting and scraping foam to avoid exposure to dust and particles that may contain isocyanates.” and to “Remove protective clothing and handle with care to avoid exposing yourself and others to toxic chemicals.”

Ventilating and isolating the work area

Ventilation is a control in its own right, and EPA’s archived ventilation guidance treats it as a layout problem for each job. It says “Properly designed ventilation can reduce airborne levels of aerosols, mists, and vapors generated during spray application and can help protect SPF applicators, helpers, and others who may be working in adjacent areas.” and “The Occupational Safety and Health Administration (OSHA) requires that engineering controls such as ventilation and enclosures be used to reduce worker exposures to acceptable levels.”

The archived ventilation guidance says “Local exhaust ventilation systems remove chemicals and other contaminants at their source.” It warns that “Simply pointing fans at the work area without establishing a directed air flow pattern will only stir up the air creating a greater potential for workers to breathe the contaminants.”

Close the space and push the air out of it. The archived ventilation guidance says “Maintain a negative pressure in the work area or enclosure.” and “This is accomplished by ensuring that you exhaust more air from the room than you supply.” It says “Remember to shut down and seal off HVAC openings in the work area to prevent migration of contaminants to other areas of the building”, and “Always remember to direct exhaust to a safe location outside the building, away from areas where other workers or people are or could be present.”

Real-World Scenario: An attic retrofit in an occupied house is on a spray foam company’s schedule, and the homeowners ask its owner whether they can stay home during the job. Before the crew arrives, she goes over the foam maker’s re-entry guidance with them, along with the plan for them to leave, and she confirms that her new helper has finished his medical evaluation and been fit tested for the tight-fitting respirator the crew uses. When the helper arrives with a full beard grown since his fit test, she holds him off the spray crew until the respirator question is settled under the written program.

Re-entry and re-occupancy after the foam is down

EPA’s archived guidance says people without protection should stay out until the foam has cured and the space has been ventilated and cleaned, and it leaves the timing to the product. EPA’s archived vacate and re-entry page says “It is not clear how much time is needed before it is safe for unprotected workers or building occupants to re-enter.” It says “During SPF installation, other trade workers and building/home occupants should vacate the premises.” and “Re-entry should be restricted until the product has finished curing, and the building has been adequately ventilated and thoroughly cleaned.”

While the area is still being ventilated after application, EPA’s archived ventilation guidance says “worker re-entry should be kept to a minimum and should only include those with appropriate respiratory protection (and skin protection if contact with the SPF is possible)” and “Occupant re-entry should only occur after the building is fully ventilated.” Its archived quick safety tips say the time some manufacturers recommend “may vary”, and tell users to “Contact your manufacturer or supplier for specific guidance on ventilation time, re-entry time, and re-occupancy time for your specific product and scenario.”

Settle the plan with the customer before the job. EPA’s archived workplace page says “EPA strongly recommends that building occupants receive clear guidance from the contractor on safe re-entry times in advance of the work to ensure there will be no exposure to SPF chemicals.”

The isocyanate program guide, and coverage for a spray foam crew

This guide covers the gear and the air; the written isocyanate program has its own guide. EPA’s archived workplace page notes that OSHA implemented a National Emphasis Program “to identify and reduce or eliminate the incidence of adverse health effects associated with occupational exposure to isocyanates.” Our isocyanate exposure control plan guide takes up the employer’s written program, and our installer job description sets out the hazards that come with the job when you hire.

EPA’s archived workplace page lists, among its tips for owners researching a contractor, “Verify the contractor’s insurance and licenses.” Our license guide covers the licensing half. For the crew, the workers’ compensation page describes that policy as an insulation business meets it, and spray foam crews have their own spray foam insurance page. The insulation business insurance overview sets those policies out together, and our spray foam margin guide takes up what vacate windows and respirators do to crew hours.

To price coverage for a spray foam crew, use the quote form to say what your crew installs and how many field employees it has.

Protecting a spray foam crew, from the written respirator program to the day the building reopens

A flow of steps for a spray foam job. Write the respirator program. Choose respirators from the hazard. Clear each worker with a medical evaluation, fit-test anyone in a tight-fitting respirator, and train before first use. Isolate and ventilate the work area. Spray in a respirator, chemical-resistant gloves and clothing, and eye protection. Keep the gear on for trimming and clean-up, and take clothing off with care. Reopen the building to occupants only after the foam has cured and the space has been ventilated and cleaned, on the manufacturer’s guidance. No figures are shown.

Frequently asked questions

Spray foam PPE requirements: what do the federal rules ask of an employer?

Where respirators are necessary, OSHA’s respiratory protection standard says the employer “shall establish and implement a written respiratory protection program with worksite-specific procedures”, and OSHA’s construction respirator rule says its requirements for construction work are “identical”. For protective clothing and other gear, OSHA’s construction PPE standard says employers must ensure it is “of safe design and construction for the work to be performed”. EPA’s archived spray foam guidance lists an “Appropriate respirator”, “Chemical resistant (e.g., nitrile) gloves” and “Chemical resistant clothing”.

Spray foam respirator requirements: which respirators does OSHA allow?

OSHA’s respiratory protection standard says “The employer shall select a NIOSH-certified respirator.” For gases and vapors in an atmosphere that is not IDLH (immediate danger to life or health), it allows “An atmosphere-supplying respirator”, or an air-purifying respirator that carries a NIOSH-certified end-of-service-life indicator or runs on a cartridge change schedule built on objective data. EPA’s archived ventilation guidance says the foam manufacturer’s respirator recommendations can be found in the product’s safety data sheet, and “Generally, these recommendations will include the use of full face-piece or hooded supplied air respirators.”

Spray foam mask: where does a dust mask fit under OSHA’s rule?

OSHA’s respiratory protection standard defines a filtering facepiece, or dust mask, as “a negative pressure particulate respirator with a filter as an integral part of the facepiece or with the entire facepiece composed of the filtering medium.” For gases and vapors in an atmosphere that is not IDLH (immediate danger to life or health), the same standard calls for “An atmosphere-supplying respirator” or an air-purifying respirator with an end-of-service-life indicator or a change schedule. EPA’s archived exposures page says “Spray application generates isocyanate vapors and aerosols.”

Spray foam insulation safety precautions: what comes before spraying starts?

EPA’s archived workplace guidance lists preparation steps: “Receive medical surveillance to ensure applicators and helpers are healthy enough to wear a respirator.” and “Vacate building occupants and other trade workers who are unprotected.” For the spraying step it adds “Isolate the work site to prevent isocyanates and other chemical vapors from spreading to other rooms or floors.” and “Ventilate the work area.” It also says to “Read the manufacturer’s label and safety data sheet (SDS) and follow directions to achieve consistent curing conditions and times.”

Spray foam safety training: what must respirator training cover?

OSHA’s respiratory protection standard says “The employer shall provide the training prior to requiring the employee to use a respirator in the workplace.” Each employee must be able to show knowledge of items that include “Why the respirator is necessary and how improper fit, usage, or maintenance can compromise the protective effect of the respirator” and “How to inspect, put on and remove, use, and check the seals of the respirator”. The standard also says “Retraining shall be administered annually”, and when workplace or respirator changes make earlier training obsolete.

Spray foam safety gear: who pays for it?

On construction work, OSHA’s construction PPE standard says “Except as provided by paragraphs (d)(2) through (d)(6) of this section, the protective equipment, including personal protective equipment (PPE), used to comply with this part, shall be provided by the employer at no cost to employees.” It adds “The employer must pay for replacement PPE, except when the employee has lost or intentionally damaged the PPE.” OSHA’s respirator standard says “The employer shall provide respirators, training, and medical evaluations at no cost to the employee.”

OSHA spray foam regulations: which standards does this guide read?

This guide reads OSHA’s respiratory protection standard, its construction respirator rule, which says the construction requirements are “identical” to that standard’s, and its construction PPE standard. EPA’s archived spray foam pages say OSHA implemented a National Emphasis Program “to identify and reduce or eliminate the incidence of adverse health effects associated with occupational exposure to isocyanates.” Our isocyanate exposure control plan guide takes up the written isocyanate program.

Spray foam safety concerns: when can the occupants come back in?

EPA ties the answer to the product rather than to a set time. Its archived re-entry page says “It is not clear how much time is needed before it is safe for unprotected workers or building occupants to re-enter.” and “Re-entry should be restricted until the product has finished curing, and the building has been adequately ventilated and thoroughly cleaned.” EPA’s contractor checklist says to “Consult SPF product manufacturer’s technical information for recommendations on ventilation and reoccupancy.”